Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Accuracy of Implant Placement Guided with Surgical Template: An In Vitro and In Vivo Study
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 41 , Issue 2
March/April 2021

Pages e55–e62


Accuracy of Implant Placement Guided with Surgical Template: An In Vitro and In Vivo Study

Miao Zhou, DDS, PhD/Hui Zhou, MS/Shu-Yi Li, MS/Xiao-Bin Yang, MS/Yuan-Ming Geng, DDS/Yue-Juan Che, MD, PhD


PMID: 33819327
DOI: 10.11607/prd.4570

This study evaluated the accuracy of implant placement with surgical-template guidance both in vitro and in vivo. Virtual surgical planning was performed based on the data from CBCT scans and an intraoral scanner. Surgical templates were designed according to the planned implants and manufactured with stereolithography. In vitro, 60 implants were placed in 15 resin models. In vivo, 74 implants were placed in 54 patients. The implants were scanned with CBCT postoperatively. Implant accuracy was evaluated by measuring the following parameters: central deviation at the apex and shoulder, horizontal deviation at the apex and shoulder, vertical deviation at the apex and shoulder, and angular deviation. There were statistically significant in vitro and in vivo deviations for all parameters, and the implant deviations in vivo were significantly greater than those in vitro. When using a mucosa-supported template, horizontal deviations at the apex were significantly greater than when a teeth-supported template was used. Within the limitation of the study design, inaccuracy existed in implant placement guided with a surgical template. More studies are needed to investigate the value of the procedure in future.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help